633 Firmware v2.11

  • New
    • Support for the new CL-12 Linear Fader Controller, including:
      • 12 100 mm linear input faders (Penny & Giles option with CL-12 Alaia)
      • L, R, X1, X2 level control, routing, arming, and 22-segment metering inc. limiter activity
      • 1 Com private line circuit
      • Numerous quick-access buttons to key functions inc. metadata, transport, TC, coms/returns, arming, routing, etc.
      • USB ports for keyboard and lamp
      • Three user-programmable buttons
      • A new CL-12 sub-menu
      • And much more…
      • Note: Not included with the CL-12, a micro USB power cord (5V) must be connected to the CL-12 DC Power Boost port in order to operate with the 633.
    • Added QR Codes for smart phone access to online documentation including Approved Media List and User Guide. A QR code reader app is required.
    • New User Bit mode allows jamming of External Timecode User Bits.
  • Fixed
    • In the File List, FAT32 media files would incorrectly display modified time instead of creation time.
    • Previously, there was a date corruption issue with ExFAT formatted media containing more than 200 files.
    • Keyboard sequence involving Shift key would sometimes repeat the same character as if the key was being held down.
    • Lock up when adding notes exceeding the 200 character limit.
    • Scene name shortcut (HP + RTN) editing factory the “None” option option causing “None” to disappear and breaking Scene Increment Mode.
    • When UBits are set to one of the date modes the UU field metadata stamps were following the take number.
    • UBits UU fields are now restored after loading user setup files.
    • Added a recheck of the real time clock to prevent false “System date error detected. Please reset time and date.” messages from appearing at boot up.